Domain 1: Water Supply

Question 1

A fertilizer-injection unit is hard-piped to a potable irrigation supply. Its booster pump can produce 95 psi while the supply is at 60 psi. The chemical mixture is a health hazard, and the design calls for a listed mechanical backflow assembly rather than an air-gap break tank. Which assembly protects against the hazard and the possible reversal mechanism?

Show answer & explanation

Correct answer: A - Reduced-pressure principle assembly, ASSE 1013.

Domain 2: Vents

Question 2

Two bathroom groups on the same floor use a correctly sized horizontal wet vent. The drainage sequence runs from the dry-vented lavatory connections through the bathtub and water-closet connections to junction J, the downstream end of the wet-vented section. A separately trapped and vented laundry standpipe is being added. Where may its drain join without disqualifying the bathroom wet vent under the 2021 IPC?

Show answer & explanation

Correct answer: C - Downstream of junction J, after the wet-vented section.

Domain 3: Fixtures and Equipment

Question 3

A lodging renovation supplies several showers through a central valve listed only to ASSE 1017. Each shower still has an ordinary two-handle faucet. Users experience abrupt temperature changes when nearby fixtures open, even though the central mixing valve works as designed. The fixture-level protection required by the 2021 IPC is:

Show answer & explanation

Correct answer: C - An individual ASSE 1016 automatic compensating valve installed at every shower.

Domain 4: General Regulations

Question 4

Before concealment, new PEX water-distribution piping must be tested for a system working pressure of 70 psi. All proposed test pressures are within the component ratings. Which procedure satisfies the 2021 IPC test requirements?

Show answer & explanation

Correct answer: A - A water test maintained at 80 psi for 20 minutes without leakage.

Domain 5: Traps, Interceptors, and Separators

Question 5

After a mechanical room has been unused for several months, sewer odor is traced to a dry floor-drain trap. Refilling the intact trap stops the odor. The vent is clear, and discharging nearby fixtures does not disturb the restored seal. The owner wants evaporation protection without adding a potable-water primer connection. Which installation is permitted by the 2021 IPC?

Show answer & explanation

Correct answer: A - Retain the P-trap and add a listed ASSE 1072 barrier-type trap-seal protection device.

Domain 6: Storm Drainage Systems

Question 6

A roof-drain submittal covers 2,400 square feet of horizontal roof projection. One 800-square-foot vertical wall drains rainwater onto that roof. The specified 100-year, 1-hour rainfall intensity is 4 inches per hour, and water head at the drain may not exceed 2 inches. Four drain options are rated at that head. Using Q = 0.0104 × rainfall intensity × effective drainage area, with Q in gpm, which is the smallest adequate rating?

Show answer & explanation

Correct answer: C - 130 gpm

Domain 7: Sanitary Drainage Systems

Question 7

A new building has basement fixtures on a finished floor at elevation 98.0 ft and ground-floor fixtures at elevation 109.0 ft. The next upstream public-sewer manhole cover is at elevation 102.4 ft. Both groups can drain by gravity, and their branches join before leaving the building. Select the backwater-valve arrangement that complies with the 2021 IPC.

Show answer & explanation

Correct answer: D - Protect only the basement branch, upstream of the junction.

Question 8

A coordination check of a 4-inch building drain records four details below. Which detail requires correction under the 2021 IPC?

Show answer & explanation

Correct answer: D - A fixed cabinet leaves 14 inches of working clearance in front of a cleanout opening.

Domain 9: Isometric Analysis

Question 9

A straight pipe spool will connect two parallel horizontal runs through a pair of 45-degree fittings. The centerlines are displaced 6 inches sideways and 8 inches vertically; both displacements are perpendicular to the original direction of the runs. Use a net fitting allowance of 1.25 inches at each end, including joint engagement. What cut length is needed, to the nearest tenth of an inch?

Show answer & explanation

Correct answer: B - 11.6 inches

Domain 11: Water Heaters

Question 10

A pressure logger on a home's cold-water piping records 58 psi with the storage water heater off. With all fixtures closed, pressure climbs gradually to 112 psi during a heating cycle, then returns to 58 psi when a faucet is briefly opened. Utility-side pressure stays steady, and the rise does not occur with the heater off. A service backflow assembly was recently installed; there is no expansion-control device. Which correction addresses the cause?

Show answer & explanation

Correct answer: A - Install a correctly sized expansion tank on the cold-water line between the backflow assembly and heater.